- Home
- Production equipment
- Board handling
- Conveyors
- ASYS VEGO Dynamic TDM 06 / Walkthrough Telescope Gate within production lines
ASYS VEGO Dynamic TDM 06 / Walkthrough Telescope Gate within production lines
The TDM 06 walkthrough telescope gate provides an intermediate passageway through a production line with no lasting effect on the production flow. The base model consists of a telescopic conveyor with a horizontal moving conveyor mechanism.
The PCB is taken over at the inlet and the horizontal conveyor extends to hand over the PCB to the downstream system. After handover, the conveyor retracts, thus opening the passageway again. This operating mode means that the passageway is only closed during PCB handover (NO-mode). An optional conveyor with lift mechanism is also available which rises to bridge the gap to the upstream machine when the bridge conveyor is extended. In this configuration, the passageway is generally closed (NC-Mode) which allows the PCBs to pass directly through the machine and results in a considerable reduction in the cycle time.
Features
Color display with graphical user interface
Product parameters can be changed during running operation
Product memory function
Electric width adjust
Adjustable passageway width (only with NO-Mode)
Available in version "open right" or "open left"
Cycle time < 15s
Operating mode:
NO: The passageway is open and is only closed for PCB handover.
Machine Configuration | 1590 | 2000 |
Transport height
Max. transport width Interface Transport path Transfer direction Operating side Fixed rail |
850mm ± 50mm
460mm SMEMA, Siemens 790 mm from left to right Front of the machine Front of the machine |
850mm ± 50mm
460mm SMEMA, Siemens 995 mm from left to right Front of the machine Front of the machine |
Panel Dimensions | ||
Panel length
Panel width Panel thickness Component clearance Panel weight |
70 to 700 mm
50 to 460 mm 0.5 to 4.5 mm ± 40mm to 3 kg |
70 to 900 mm
50 to 460 mm 0.5 to 4.5 mm ± 40mm to 3 kg |
Installation Requirements | ||
Power supply
Power supply system Power consumption Air supply Air consumption |
230 V / 115 V, 50 / 60 Hz, ± 10%
L1 + N + PE 0.2kW 6 bar 10 Nl/min |
230 V / 115 V, 50 / 60 Hz, ± 10%
L1 + N + PE 0.2kW 6 bar 10 Nl/min |
Machine Description | ||
Length x Width x Height
Net weight Noise Level |
1590 x 1000 x 960 mm
235 kg < 75 dB |
2000 x 1000 x 960 mm
300 kg < 75 dB |